Now that you have finished reviewing all course material, it’s time to take the final exam. You must score 70% or higher to pass this exam. You will have an unlimited number of attempts to pass and there is no time limit for each attempt. Once you pass, you will receive a certificate of completion. Good luck!
0 of 20 Questions completed
Questions:
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
0 of 20 Questions answered correctly
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
You must score 70% or higher to pass this exam. You get unlimited attempts to pass. Please review the course material and attempt this exam again. Once you pass, you will receive a certificate of completion. Click the Restart Quiz button to take this quiz again.
Congratulations – You Passed the Course Exam. Click the “Continue” button to view your certificate of completion.
What size distributor room should be allocated for 500 sq. m (5000 sq. ft.) or less of usable floor space in a commercial building?
The bottom of the plywood backboard will normally be installed ____ to _____ inches above the distributor room floor.
What clearance must be allocated behind communication racks in a distributor room?
Industry standards recommended installing a minimum of _____, trade size 4 conduits between vertically aligned distributor rooms.
The ANSI/TIA-569-D standard permits a conduit fill percentage of _____ of the conduits internal diameter when installing one cable.
As a general rule, the industry standards and best practices documents recommend a maximum fill ratio of _____ of the pathway’s capacity.
The backbone cabling subsystem must be designed to support the current and future needs of the building it serves for ____ to ____ years.
What is the maximum distance supported by UTP cable in the backbone subsystem from the MC to DR?
What is the maximum distance supported for singlemode fiber cable in the backbone subsystem from the MC to DR?
Large capacity enclosed ducts terminate using an elbow at a plywood lined wall. The elbow must terminate a minimum of ______ above the finished floor of the DR.
Ducts are sized for _____ of capacity for each 10 sq. m (100 sq. ft.) of usable floor space.
Conduit runs must be limited to a maximum distance of ________ from the distributor room to the outlet box in the work area.
Industry cabling standards require that all application specific devices must be installed in the work area subsystem.
Category 5e cable is rated up to what frequency?
50/125 multimode optical fiber horizontal cable must exhibit a maximum of ____ loss at 850 nm.
What is the maximum length for work area cables?
The T568A modular configuration has the orange pair terminated on what pins?
The MUTOA must be limited to serving a maximum of ______ work area locations.
What standard defines and specifies the commercial building grounding and bonding requirements for telecommunications?
The ANSI/TIA-607-C standard requires that a bonding conductor is used to connect the telecommunications grounding and bonding system to the building grounding system.